There is a new Software for the Wyse P20 Client. There a new Firmware, WDM Package and Management Software for the P20 Client
You can read the release notes Here.
Downloads:
Wyse P20 Firmware
There is a new Software for the Wyse P20 Client. There a new Firmware, WDM Package and Management Software for the P20 Client
You can read the release notes Here.
Downloads:
Wyse P20 Firmware
I had a problem with a Thinapp Capture: Target .dat does not exist or is not data container because it does not have a ReadOnlyData= Setting
The executable "chemiekaarten 2011.exe" links to a primairy datacontainer "Chemiekaarten.dat". Deze wordt niet gevonden in package.ini
Delete the following rule Shortcut= after [chemiekaarten 2011.exe] at package.ini and add the follow ing ReadOnlyData=bin\Package.ro.tvr.
Thanks to my college Edwin
Support for Windows 7 SP1
Workstation 7.1.4 addresses a local privilege escalation in the vmrun utility
VMware vmrun is a utility that is used to perform various tasks on virtual machines. The vmrun utility runs on any platform with VIX libraries installed. It is installed in Workstation by default. In non-standard filesystem configurations, an attacker with the ability to place files into a predefined library path could take execution control of vmrun. This issue is present only in the version of vmrun that runs on Linux
The Common Vulnerabilities and Exposures project (cve.mitre.org) has assigned the name CVE-2011-1126 to this issue.
In Workstation 7.1, the default main memory VA cache size (mainMem.vaCacheSize) for 32-bit Windows guests was reduced to accommodate 3D emulation memory requirements. However, the reduced value resulted in performance loss. For 7.1.4, the default main memory VA cache size has been be increased to 1000 MB and performance is improved.
Because Workstation failed to identify more than 10 USB host controllers in newer Windows guests, some USB devices did not appear in the Removable Devices menu. Now Workstation shows all USB devices in the Removable Devices menu as long as they are connected to the first identified 16 USB controllers.
When using the Capture Movie option, the captured video stopped playing around the 1GB mark if the video file exceeded 1GB. Now you can capture and play video files that are greater than 1GB.
On Windows host systems that have more than 4GB of memory, Workstation sometimes crashed during cryptographic operations, for example, when performing disk encryption.
VMware Tools upgrade could be started by a non-administrator user from the VMware Tools Control Panel in a Windows guest. In this release, only administrator users can start VMware Tools upgrade from the VMware Tools Control Panel. To prevent non-administrator users from starting VMware Tools upgrade from a guest by using other applications, set isolation.tools.autoinstall.disable to TRUE in the virtual machine configuration (.vmx) file.
When a virtual machine running on a Windows host was used to access an Omron Industrial CP1L Programmable Logic Controller, Workstation generated an unrecoverable error.
When using NAT virtual networking on Windows hosts, the traceroute command did not work when used within virtual machines.
Workstation crashed with an access violation when a user tried to open the sidebar after closing all tabs in Quick Switch mode.
The VMware Tools HGFS provider DLL caused a deadlock when making calls to the WNetAddConnection2 function from an application such as eEye Rentina in a Windows guest operating system.
There was no option to disable guest time sync when a host resumes. Now you can set time.synchronize.resume.host to FALSE in the virtual machine configuration (.vmx) file to disable guest time sync when a host resumes. See VMware Knowledge Base Article 1189 for other time sync options.
Setting a hidden attribute on a file in a shared folder from a Windows guest on a Linux host failed with an error. This problem caused applications such as SVN checkout to fail when checking out to shared folders on Linux hosts from Windows guests
VMware released VMWare View 4.6
Updated Features:
Security servers can now accommodate PCoIP connections – Security servers now include a PCoIP Secure Gateway component. The PCoIP Secure Gateway connection offers the following advantages:
Enhanced USB device compatibility – View 4.6 supports USB redirection for syncing and managing iPhones and iPads with View desktops. This release also includes improvements for using USB scanners, and adds to the list of USB printers that you can use with thin clients. For more information, see the list of View Client resolved issues.
Keyboard mapping improvements – Many keyboard-related issues have been fixed. For more information, see the list of View Client resolved issues.
New timeout setting for SSO users – With the single-sign-on (SSO) feature, after users authenticate to View Connection Server, they are automatically logged in to their View desktop operating systems. This new timeout setting allows administrators to limit the number of minutes that the SSO feature is valid for.
For example, if an administrator sets the time limit to 10 minutes, then 10 minutes after the user authenticates to View Connection Server, the automatic login ability expires. If the user then walks away from the desktop and it becomes inactive, when the user returns, the user is prompted for login credentials. For more information, see the VMware View Administration documentation.
VMware View 4.6 includes more than 160 bug fixes – For descriptions of selected resolved issues, see Resolved Issues.
Support for Microsoft Windows 7 SP1 operating systems (Not Experimental of RC wrong on the VMware site)
VDI Documentation
VMware View 4.6 Release Notes
VMware View Architecture Planning
VMware View Administration
VMware View Installation
VMware View Upgrades
VMware View Integration
This issue occurs when you have installed one of these Microsoft patches, 2482017 or 2467023.
If you have already installed these patches, you can install VMware View Client (build 353760) or uninstall the Microsoft patches.
If you have not installed these patches, delay the installation of the Microsoft patches until you have installed VMware View Client (build 353760).
VMware View Client build 353760 has been tested on:
The View Client patch can be downloaded from here. Enter your credentials, accept the EULA and download the appropriate file:
To apply this patch
Very Important: VMware View Clients with build number 353760 or later are not affected by this issue.
VMWare has released VMware Workstation 7.1.
What’s New in VMware Workstation 7.1
Download VMware Workstation HERE. You need a valid VMware Account to download.
Group Policy settings die je moet zetten onder Remote Desktop
VMWare View Client GPO settings
– Enable the shade
– Pin the shade
– Don’t check monitor alignment on spanning
– Color depth
– Desktop background
– Show contents of window while dragging
– Menu and window animation
– Themes
– Cursor shadow
– Font smoothing
– Desktop composition
– Audio redirection
– Redirect drives
– Redirect printers
– Redirect serial ports
– Redirect smart cards
– Redirect clipboard
– Redirect supported plug-and-play devices
– Bitmap caching
– Shadow bitmaps
– Cache persistence active
– Enable compression
– Windows key combination redirection
– Bitmap cache file size
The VMware View ADM files can be found on the following place:
“C:\Program Files\VMware\VMware View\Server\Extras\GroupPolicyFiles”
– vdm_agent.adm contains properties relating to the authentication and
environmental components of a client desktop controlled by View Agent
- vdm_client.adm contains properties relating to the configuration parameters of
View Client
– vdm_server.adm contains properties relating to View Connection Server
– vdm_common.adm contains properties relating to all components of View Manager
– pcoip.adm PCOIP Performance properties
Meer hierover vindt je in VMWare View Manager Administration Guide & VMWare XP deployment Guide
Installatie XP
1. Windows XP SP3 ISO nodig
2. Maak een XP virtuele machine aan met een buslogic harddisk van 16GB en 512MB geheugen
2. Maak een een harddisk aan van SCSI harddisk aan van 16GB.
3. Boot vanaf de ISO
4. Mount the vmscsi-1.2.0.2.flp”
5. Op de VM ga naar edit settings en dan naar de Options tab en in General gedeelte haal het vinkje weg bij Enable logging.
6. Na installatie Verwijder the Serial, Parallel and Floppy ports.
7. Installeer VMWare Tools custom zonder de Shared Folders driver.
8. Installeer de VMWare View Client
9. Werk de VM helemaal bij zonder de volgende updates.
– Microsoft Base Smart Card Cryptographic Service Provider Package: x86
– Microsoft Windows Search 4.0 for Windows XP
Configuren van de XP Template
1. Deze Computer, Advanced tabblad, Performance settings. Kies voor “Adjust for best performance”.
2. Disable Automatisch Updates
3. Turn Off System Restore
4. Verwijder alle overbodige Windows Componenten.
5. Open User Accounts, click Change the way users log on or off, Uncheck both boxes .
6. Verwijder alle overbodige snelkoppelingen onder All Users Profiel.
7. Disable de volgende services:
– Computer Browser
– Help and Support
– Indexing Service
– IPSec Service
– Network Local Awareness
– Security Center
– Shell Hardware Detection
– SSDP Discovery Service
– System Restore Service
– Task Scheduler
– Themes
– Windows Firewall/Internet Connection Sharing (ICS)
– Wireless Zero Configuration
8. Start –> Run –> FSUTIL behavior set disablelastaccess 1
9. Start –> Run –> sfc /purgecache
10. Start –> Run –> sfc /cachesize=0
11. Start –> Run –> Regsvr32.exe /u msutb.dll
12. Start –> Settings –> Printers and Faxes.
File, Server Properties, Advanced tab verwijder alle vinkjes
13. Installeer User Profile Hive Cleanup Service
14. Start –> Control Panel –> Network Connections –> LAN –> Properties Internet Protocol (TCP/IP)
–> Properties > Stel het IP address van je DNS Servers in.
15. Verwijder alle overbodige mappen. Zoals C:\WINDOWS\$hf_mig$
16. Draai Disk Clean Up
17. Defragmenteer de Schijf
18. Vergeet ook niet op RDP aan te zetten
19. Maak een nieuwe gebruiker aan en configureer dit profiel en als je klaar bent log dan in met administrator account en kopieer het profiel naar de default user
20. Verwijder de tijdelijke gebruiker die je hier voor hebt aangemaakt.
21. Zet de VM uit en maak een snapshot en convert to template.
Prerequisites
VMware View Connection Server
• Pentium IV 2.0Ghz processor or higher — dual processors are recommended
• 2GB RAM or higher — 3GB RAM is recommended for deployments of 50 or more View Manager desktops. VMware View connection server can handle 2,000 connections in clear mode and 750 in tunneled mode.
• One or more 10/100Mbps network interface controllers (NIC) — 1Gbps NIC is recommended
Supported Operating Systems
The VMware View Connection Server can be installed on the following 32-bit operating systems:
• Windows Server 2003 R2 Standard Edition with SP2
• Windows Server 2003 Standard Edition with SP2
• Windows Server 2003 R2 Enterprise Edition with SP2
• Windows Server 2003 Enterprise Edition with SP2
VMware View Connection Server Licences:
• VMware View Manager
• VMware View Manager with View Composer
• VMware View Manager with View Composer, and Offline Desktop