Ultimate Cross vCenter Script

Last year i attend the Dutch VMUG (NLVMUG) i followed session from

Michael Wilmsen that was: Migrate your datacenter without downtime.

I must also move al lot of VM’s from different datacenters to other datacenters.
I use the script from Michael Wilmsen to move the VM’s. But along the way I counter some problems with this script. So I begon tweaking and tweaking and tweaking this script to create for me the ultimate Cross vCenter PowerCLI Script.

Coolfeatures:
– Info through Whattsapp (Default not enabled)
– Dryrun (Test Run)
– Logging
– Selection through GUI
– Multiple Nic support maximum of 4.
– Datastore en Host selection based on Free space en Free Memory
– Check of Destination Host or Datastore in Maintance
– Destination Store exist in Destination Cluster

MoveVM.ps1:
#Filename: MoveVM.ps1
#Author: M. Wilmsen / W. Vissers
#Source: http://virtual-hike.com/nlvmug-2018/
#Version: 2.0
#Date: 21-10-2018
#ChangeLog:
# V0.9 – M. Wilmsen First Version
# V1.0 – Fixed Multiple Nics to maximium of 4 nics
#      – Logfile name VM name
# V1.1 – Destination Cluster not the first Host
# V1.2 – Selected Destination host based on memory used
# V1.3 – Fixed folder location and VirtualPortGroup
# V1.4 – Fixed Datastore in Maintance
# V1.5 – Using Get-VICredentialStoreItem + Logpath Fixt
# V1.6 – Fixed Log in Hours in 24 uurs
# V1.7 – Fixed Using DatastoreCluster name based on Cluster name!
# V1.8 – Check if Destination has the same datastore
#          – Ask know for input
#          – VM selection with VMhost
#          – Fixed Ping Check
# v1.9 – Added Destination Store exist in Destination Cluster
# v2.0 – Fixed Destination Store exist in Destination Cluster
<#
.SYNOPSIS
Script to migrate a virtual machine
.DESCRIPTION
Script to migrate compute and storage from cluster to cluster. Log will be in current dir [VM]-[-timestamp].log

.EXAMPLE
MoveVM.ps1
#>
################################## INIT #################################################
#Set WebOperation timeout
# set-PowerCLIConfiguration -WebOperationTimeoutSeconds 3600
#Define Global variables
$location = “D:\xmovewhattsapp”
$LogPath = “.\”
$DataStoreClusterPrefix = “SAN-“
$SourceVC = Read-Host “Give Source vCenter”
$DestinationVC = Read-Host “Give Destination vCenter”
$DRSRecommendation = $true
$Dryrun = $false
$SendWhatsApp = $false
$WhatsAppNumbers = “0123456789”
$WhatsAppGroup = “Namehireyourwhattsgroup”
$instanceId = “23” #chang this line
$clientId = “demo@demo.nl” #change this line
$clientSecret = “Puthiersecretid” #change this line
################################## PASSWORD STORE ##############################################
#Username
# Check if credentials exist in credential store if not ask for credentials and put them in credential store

If ((Get-VICredentialStoreItem).host -notcontains $SourceVC) {New-VICredentialStoreItem -Host $SourceVC -User $env:USERNAME -Password ((get-credential).GetNetworkCredential().Password)}
If ((Get-VICredentialStoreItem).host -notcontains $DestinationVC) {New-VICredentialStoreItem -Host $DestinationVC -User $env:USERNAME -Password ((get-credential).GetNetworkCredential().Password)}

# Remove-VICredentialStoreItem * -Confirm:$false

################################## END INIT #################################################
################################## FUNCTIONS #################################################
#Define log function
Function LogWrite
{
    Param ([string]$logstring)
    #Add logtime to entry
    $LogTime = Get-Date -Format “MM-dd-yyyy_HH-mm-ss”
    $logstring = $LogTime + ” : ” + $logstring
    #Write logstring
    Add-content $LogFile -value $logstring
    Write-Host $logstring
}
#Define SendWhatsApp function
Function SendWhatsApp
{
   Param ([string] $message)
  
   if ( $SendWhatsApp ) {
     $LogTime = Get-Date -Format “MM-dd-yyyy_hh-mm-ss”
     $message = $logtime + ” : ” + $message
    
     foreach ( $number in $WhatsAppNumbers )
     {
        $jsonObj = @{‘group_admin’=$number;
                     ‘group_name’=$WhatsAppGroup;
                     ‘message’=$message;}
       Try {
         $res = Invoke-WebRequest -Uri “http://api.whatsmate.net/v2/whatsapp/group/message/$instanceId” `
                           -Method Post   `
                           -Headers @{“X-WM-CLIENT-ID”=$clientId; “X-WM-CLIENT-SECRET”=$clientSecret;} `
                           -Body (ConvertTo-Json $jsonObj)
         LogWrite “WhatsMate Status Code: ”  $res.StatusCode
         LogWrite $res.Content
       }
       Catch {
         $result = $_.Exception.Response.GetResponseStream()
         $reader = New-Object System.IO.StreamReader($result)
         $reader.BaseStream.Position = 0
         $reader.DiscardBufferedData()
         $responseBody = $reader.ReadToEnd();

        Write-host “Status Code: ” $_.Exception.Response.StatusCode
         Write-host $message
         }
     }
   }
}

function Get-VmSize($vm)
{
     #Initialize variables
     $VmDirs =@()
     $VmSize = 0
     $searchSpec = New-Object VMware.Vim.HostDatastoreBrowserSearchSpec
     $searchSpec.details = New-Object VMware.Vim.FileQueryFlags
     $searchSpec.details.fileSize = $TRUE
     Get-View -VIObject $vm | % {
         #Create an array with the vm’s directories
         $VmDirs += $_.Config.Files.VmPathName.split(“/”)[0]
         $VmDirs += $_.Config.Files.SnapshotDirectory.split(“/”)[0]
         $VmDirs += $_.Config.Files.SuspendDirectory.split(“/”)[0]
         $VmDirs += $_.Config.Files.LogDirectory.split(“/”)[0]
         #Add directories of the vm’s virtual disk files
         foreach ($disk in $_.Layout.Disk) {
             foreach ($diskfile in $disk.diskfile){
                 $VmDirs += $diskfile.split(“/”)[0]
             }
         }
         #Only take unique array items
         $VmDirs = $VmDirs | Sort | Get-Unique
         foreach ($dir in $VmDirs){
             $ds = Get-Datastore ($dir.split(“[“)[1]).split(“]”)[0]
             $dsb = Get-View (($ds | get-view).Browser)
             $taskMoRef  = $dsb.SearchDatastoreSubFolders_Task($dir,$searchSpec)
             $task = Get-View $taskMoRef
             while($task.Info.State -eq “running” -or $task.Info.State -eq “queued”){$task = Get-View $taskMoRef }
             foreach ($result in $task.Info.Result){
                 foreach ($file in $result.File){
                     $VmSize += $file.FileSize
                 }
             }
         }
     }
     return $VmSize
}
################################## END FUNCTIONS #################################################
#Login to vCenter servers
if (($global:DefaultVIServers).Name -notcontains $SourceVC -or $DestinationVC) {

#SourceVC
$ConnectVC = Connect-VIServer $SourceVC
$Message = “Connecting to ” + $ConnectVC  + ” as ” + $env:USERNAME
#Logwrite $Message
#DestionationVC
$ConnectVC = Connect-VIServer $DestinationVC
$Message = “Connecting ” + $ConnectVC + ” as ” + $env:USERNAME
#Logwrite $Message

# Disconnect-VIServer * -Confirm:$false

}
Set-Location $location

$cluster=Get-Cluster -Server $SourceVC  | Out-GridView -OutputMode Single -Title “Select Source Cluster”
$vmtomigrate =Get-Cluster $cluster -Server $SourceVC | Get-VM | Out-GridView -OutputMode Single -Title “Select VM”
$DestinationCluster = Get-Cluster -Server $DestinationVC | Out-GridView -OutputMode Single -Title “Select Destination Cluster”
$vmfolder=Get-folder -Server $DestinationVC | Out-GridView -OutputMode Single -Title “Select Folder”

#Main Script

    #Set $MigError to false befor migration
     $MigError = $false
     #Get VM variables
     $vm = get-vm $vmtomigrate
    
     #Define LogFile with time stamp
     $LogTime = Get-Date -Format “MM-dd-yyyy_hh-mm-ss”
    
     if([IO.Directory]::Exists($LogPath))
     {
     #Do Nothing!!
     }
     else
     {
     New-Item -ItemType directory -Path $LogPath
     }
     $LogFile = $LogPath+$VM+”-“+$LogTime+”.log”
    
     # LogWrite Gebruiker
    
     Logwrite $env:USERNAME

    # Get-VM Info   
    
     $VMHDDSize = Get-VmSize($vm)
     $VMHDDSize = [Math]::Round(($VMHDDSize / 1GB),2)

    Logwrite “Start Virtual Machine Move”
     #If WhatsApp make notice
     if ( $SendWhatsApp ) { LogWrite “Notifications will be send using WhatsApp to WhatsApp Group: $WhatsAppGroup” }
     #If DryRun make Notice
     if ( $Dryrun ) {
     Logwrite “Start move virtual machines $vm Disksize $VMHDDSize GB (DryRun)”
     SendWhatsApp “Start move virtual machines $vm Disksize $VMHDDSize GB(DryRun)”
     }
     else {
     Logwrite “Start move virtual machines $vm Disksize $VMHDDSize GB”
     SendWhatsApp “Start move virtual machines $vm Disksize $VMHDDSize GB”
     }
     $SourceCluster = get-vm $vm | Get-Cluster | select name
     $vmip = $vm  | Select @{N=”IP Address”;E={@($_.guest.IPAddress[0])}}
     $vmip = $vmip.”ip address”
     $VMHDDSize = Get-VmSize($vm)
     $VMHDDSize = [Math]::Round(($VMHDDSize / 1GB),2)
     $NetworkAdapter = Get-NetworkAdapter -VM $vm -Server $SourceVC
     $SourceVMPortGroup = Get-NetworkAdapter -vm $vm | Select NetworkName
     $switchname = $DestinationCluster
    

     $Datastore = Get-VM $vm | Get-DataStore -Server $sourceVC | Select @{N=”Name”;E={@($_.Name)}}
     $Datastore = $Datastore.Name
     $DatastoreExistinOthervCenter = Get-Cluster $DestinationCluster | Get-DataStore -Server $DestinationVC | ? {$_.Name -like “*$Datastore*”}

     if ($DatastoreExistinOthervCenter )
      {
      LogWrite  “Datastore exsist $DestinationCluster in  destination vCenter $DestinationVC “
      $destinationDatastore = $DatastoreExistinOthervCenter }
      Else
      {
      LogWrite  “Datastore does not exsist in $DestinationCluster destination vCenter $DestinationVC”
      # Select DataStore with the most free space and not in maintance
      $DatastoreCluster = “$DataStoreClusterPrefix”+”$DestinationCluster”
      $destinationDatastore = Get-DatastoreCluster $DatastoreCluster | Get-Datastore | Where {$_.State -ne “Maintenance”} | Sort-Object -Property FreeSpaceGB -Descending | Select-Object -First 1
      }

     $destinationDatastoreFreeSpace = $destinationDatastore | Select Name,@{N=”FreeSpace”;E={$_.ExtensionData.Summary.FreeSpace}}
      $destinationDatastoreFreeSpace = [Math]::Round(($destinationDatastoreFreeSpace.”FreeSpace” / 1GB),2)

    # Select the host with the less used memory
   
     $DestinationHost = Get-Cluster –Name $DestinationCluster –Server $DestinationVC | Get-VMhost -State Connected | Sort-Object -Property MemoryUsageGB | Select-Object -First 1
            
     # Change Here if you have a vm with multiple Network Cards (Remove the # for the multiple nics)
    
     if ($NetworkAdapter.Count-eq 1) {
         $DestinationVMPortgroup =@()
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic1”
      }
     elseif ($NetworkAdapter.Count-eq 2) {
         $DestinationVMPortgroup =@()
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic1”
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic2”
     }
     elseif ($NetworkAdapter.Count-eq 3) {
         $DestinationVMPortgroup =@()
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic1”
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic2”
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic3”
     }
     elseif ($NetworkAdapter.Count-eq 4) {
         $DestinationVMPortgroup =@()
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic1”
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic2”
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic3”
         $DestinationVMPortgroup += Get-VirtualPortGroup -Server $DestinationVC -Vmhost $DestinationHost | Out-GridView -OutputMode Single -Title “Select Nic4”
     }

    LogWrite “Start move: $vm”
     Logwrite “VM IP: $vmip”
     Logwrite “VM Disk Used (GB): $VMHDDSize”
     Logwrite “VM Folder: $vmfolder”
     Logwrite “Source vCenter: $SourceVC”
     Logwrite “VM Source Cluster: $SourceCluster”
     Logwrite “Destination vCenter: $DestinationVC”
     Logwrite “VM Destination Cluster: $DestinationCluster”
     Logwrite “Destination host: $DestinationHost”
     LogWrite “VM Source PortGroup: $SourceVMPortGroup”
     LogWrite “VM Destination Portgroup: $DestinationVMPortgroup”
     Logwrite “VM Destination Datastore: $destinationDatastore”
     LogWrite “Destination Datastore FreeSpace GB: $destinationDatastoreFreeSpace “
     if ( $Dryrun ) {
       $FreespaceAfterMigration = $destinationDatastoreFreeSpace – $VMHDDSize
       if ( $FreespaceAfterMigration -lt 0 ) { Logwrite “ERROR: Datastore $destinationDatastore does not have sufficient freespace! Virtual Machine needs $VMHDDSize. Only $destinationDatastoreFreeSpace available.” }
       else { Logwrite “Virtual Machine will fit on datastore $destinationDatastore. Freespace after migration is: $FreespaceAfterMigration GB” }
     }
    #Test if VM responsed to ping
    if ($vmip -eq $null) {
     LogWrite “Virtual Machine ip address not known”
     Logwrite “No ping check will be performed after moving the Virtual Machine”
     }
    else {
         Test-Connection -comp $vmip -quiet
         LogWrite “Virtual Machine $vm response to ping before being moved. Virtual machine will be checked after being moved”
         $PingVM = $true
     }
      
     #if ( $VMHDDSize -eq
     if ( -NOT $Dryrun) {
       #Migrate VM to cluster
       LogWrite “Move $vm to vCenter $DestinationVC and datastore $DestinationDatastore”
       Try {
         $Result = Move-VM -VM $vm `
                            -Destination $DestinationHost `
                            -Datastore $DestinationDatastore `
                            -NetworkAdapter $NetworkAdapter `
                            -PortGroup $DestinationVMPortgroup `
                            -ErrorAction Stop
           }
       Catch {
         $ErrorMessage = $_.Exception.Message
         LogWrite “ERROR: Move of $vm to cluster $DestinationHost failed!!!”
         Logwrite “ERROR: Move Status Code:  $ErrorMessage”
         SendWhatsApp “ERROR: Move of $vm failed!!! $ErrorMessage”
         $MigError = $true   
       }
       #Migrate VM to folder
       LogWrite “Move $vm to vCenter $vmfolder”
       Try {
         $VMtemp = get-vm $vm
         $Result = Move-VM -VM $vmtemp -InventoryLocation $vmfolder -ErrorAction Stop
           }
       Catch {
         $ErrorMessage = $_.Exception.Message
         LogWrite “ERROR: Move of $vm to folder $vmfolder failed!!!”
         Logwrite “ERROR: Move Status Code:  $ErrorMessage”
         SendWhatsApp “ERROR: Move of $vm failed!!! $ErrorMessage”
         $MigError = $true   
         }
       }
    
     $MigError = $false
     #Test if VM is running on destination cluster
     if ( -NOT $MigError -AND -NOT $Dryrun ) {
       LogWrite “Check $vm is registered in $DestinationVC”
       try {
         $CheckVM = get-vm -name $vm -server $DestinationVC -ErrorAction Stop
 
         if ( $CheckVM ) {
           Logwrite “$vm registered in $DestinationVC”
         }
         else {
           Logwrite “ERROR: $vm not found in $DestinationVC”
         }
       }
       catch {
         $ErrorMessage = $_.Exception.Message
         Logwrite “ERROR: $vm not found in $DestinationVC”
         Logwrite “ERROR: $ErrorMessage”
         SendWhatsApp “ERROR move: $vm not found in $DestinationVC”
       }
     }
     #Test is VM response to ping, if $PingVM = $True
     if ($PingVM) {
       if (Test-Connection -comp $vmip -quiet) {
         LogWrite “Virtual Machine $vm response to ping after move”
         SendWhatsApp “Virtual Machine $vm response to ping after move”
       } 
     }
     sleep 1
     SendWhatsApp “Finished move action: $vm from $SourceVC to $DestinationVC”
     Logwrite “Finished move action: $vm from $SourceVC to $DestinationVC”

if ($DRSRecommendation)
  {
   Get-DrsRecommendation -Cluster $DestinationCluster -Server $DestinationVC | Apply-DrsRecommendation
   Logwrite “DRS Recommendatation applyed”
  }
Else
  {
  Logwrite “No DRS Recommendatation applyed”
  Write-Host “No DRS Recommendatation applyed”
  }  
 

#Disconnect from vCenter servers
Logwrite “Disconnect from vCenter servers $SourceVC $DestinationVC”
Disconnect-viserver $SourceVC -Confirm:$false
Disconnect-viserver $DestinationVC -Confirm:$false
Logwrite “Finished moving virtual machines, exiting…..”
SendWhatsApp “Finished moving virtual machines, exiting…..”

VMware vSphere PowerCLI 11.0

VMware vSphere PowerCLI 11.0 New Features

New features available on  VMware vSphere PowerCLI 11.0 is to support the new all updates and release of VMware products , find the below following has been features,

  • New Security module
  • vSphere 6.7 Update 1
  • NSX-T 2.3
  • Horizon View 7.6
  • vCloud Director 9.5
  • Host Profiles – new cmdlets for interacting with
  • New Storage Module updates
  • NSX-T in VMware Cloud on AWS
  • Cloud module multiplatform support
  • Get-ErrorReport cmdlet has been updated
  • PCloud module has been removed
  • HA module has been removed

Now we will go through above mentioned new features to find what functionality it bring to PowerCLI 11.0

What is PowerCLI 11.0 New Security Module

The new security module brings more powerful automation features to PowerCLI 11.0 available  new cmdlets include the following

  • Get-SecurityInfo
  • Get-VTpm
  • Get-VTpmCertificate
  • Get-VTpmCSR
  • New-VTpm
  • Remove-VTpm
  • Set-VTpm
  • Unlock-VM

Also New-VM cmdlet has enhanced functionality with the security module functionality and it includes parameters like KmsCluster, StoragePolicy, SkipHardDisks etc which can be used while creating new virtual machines with PowerCLI .In addition to that  Set-VM, Set-VMHost, Set-HardDisk, and New-HardDisk cmdlets are added.

Host Profile Additions

There are few additions to the VMware.VimAutomation.Core module that will make managing host profiles from PowerCLI

  • Get-VMHostProfileUserConfiguration
  • Set-VMHostProfileUserConfiguration
  • Get-VMHostProfileStorageDeviceConfiguration
  • Set-VMHostProfileStorageDeviceConfiguration
  • Get-VMHostProfileImageCacheConfiguration
  • Set-VMHostProfileImageCacheConfiguration
  • Get-VMHostProfileVmPortGroupConfiguration
  • Set-VMHostProfileVmPortGroupConfiguration

Storage Module Updates

These new Storage Module updates specifically for VMware vSAN , the updates has predefined time ranges when using Get-VsanStat. In addition  Get-VsanDisk has additional new properites that are returned including capacity, used percentage, and reserved percentage. Following are the  cmdlets have been added to automate vSAN

  • Get-VsanObject
  • Get-VsanComponent
  • Get-VsanEvacuationPlan – provides information regarding bringing a host into maintenance mode and the impact of the operation on the data, movement, etc

Additionally  following modules have been removed

  • PCloud module
  • HA module

Download now and start using

Update-module VMware.Powercli

Useful Links

vSphere 6.7 Update 1 Ready for Download

VMware vSphere Hypervisor (ESXi) 6.7U1
2018-10-16
Go to Downloads

VMware vCenter Server 6.7U1
2018-10-16
Go to Downloads

VMware vRealize® Log Insight™ 4.6.1 for vCenter™
2018-06-05
Go to Downloads

VMware vSphere Replication 8.1.0.4
2018-08-24
Go to Downloads

VMware vRealize Orchestrator Appliance 7.5.0
2018-09-20
Go to Downloads

VMware vRealize Operations Manager 7.0
2018-09-20
Go to Downloads

VMware NSX for vSphere 6.4.3
2018-09-11
Go to Downloads

HPE Oneview Powershell Clear Alerts

You need: https://github.com/HewlettPackard/POSH-HPOneView/wiki

################################################################
#
#Naam:              Oneview Clear Alarms
#Version:           0.1
#Author:            Ward Vissers
################################################################

 

# Adding PowerCLI core snapin, also check if powerCLI module is alsready added

if (!(get-module -name HPOneView.400 -erroraction silentlycontinue)) {
import-module HPOneView.400 | out-null
}

 

$oneviewserver = “oneview.wardvissers.nl”
Connect-HPOVMgmt -Hostname $oneviewserver
Get-HPOVAlert | Set-HPOVAlert -Cleared
Get-HPOVAlert -State Active | Set-HPOVAlert -Cleared

PowerCLI Move All VM’s to other Host

################### Config ##################################

$SourceVC = “vcenter.wardvissers.nl

################## PASSWORD STORE #########################

#Username

# Check if credentials exist in credential store if not ask for credentials and put them in credential store

 

If ((Get-VICredentialStoreItem).host -notcontains $SourceVC) {New-VICredentialStoreItem -Host $SourceVC -User $env:USERNAME -Password ((get-credential).GetNetworkCredential().Password)}

 

# Remove-VICredentialStoreItem * -Confirm:$false

 

#################### END INIT ####################################

 

#Login to vCenter servers

if (($global:DefaultVIServers).Name -notcontains $SourceVC) {

 

#SourceVC

$ConnectVC = Connect-VIServer $SourceVC

 

# Get-Cluster –Name $DestinationCluster –Server $DestinationVC | Get-VMhost -State Connected | Sort-Object -Property MemoryUsageGB | Select-Object -First 1

 

$ESXiHostSrc = “esx01.wardvissers.nl”

$ESXiHostDst = “esx02.wardvissers.nl”

$vmList = Get-VMHost $ESXiHostSrc | Get-VM

$vmList | move-vm -destination (get-vmhost $ESXiHostDst)

}

PowerCLI move Multiple VM’s to a VM Folder

$DestinationVC = “vcenter.wardvissers.nl”

Connect-VIServer $DestinationVC

#Optie 1

$vmfolder = “Applicatie Servers”

$tempvms = Get-VM | where {$_.Folder -match ‘vm’}

foreach ($tempvm in $tempvms){

$DestinationHost = Get-VM $tempvm | Get-VMhost

Move-VM -VM $tempvm -InventoryLocation $vmfolder -Destination $DestinationHost -ErrorAction Stop

}

#Optie 2

# Get-VM | where {$_.Folder -match ‘vm’} | Move-VM -InventoryLocation “Diverse Applicatie Servers”

Deploy Multi VM’s based on Windows Template

I love powershell. I created a little script to deploy multi VM based on a Windows Template throug CSV file.

It’s create a computer account at the specfified ou. He greates also a Domain Local Group for management. (It used in the customization not specified here)

TempVMlist.csv

server,cpu,memory,DestinationCluster,OSCustomizationSpec,VMtemplate,adgroup

WARDTEST01,2,8,CLUSTER01,W2012R2_Demo,TPL_W2012R2_STD,ServerAdmin

MultiVM.ps1

#Filename: MultiVM.ps1

#Author: W. Vissers

#Source:

#Version: 1.1

#Date: 08-05-2018

#ChangeLog:

# V1.0 – Module Active Directory

#      – Module VMware PowerCli

#      – Active Directory Computer Account, Group

#      – Host Selected from Cluster with Least Memory

#      – Storage selection based on volume with most free space

# V1.1 – Added Harddisk 1&2

#      – Changed porte group other vlan

#

<#

.SYNOPSIS

Script to create a virtual machine from template

.DESCRIPTION

Script to create a virtual machine from template

.EXAMPLE

MultiVM.ps1

#>

################################## INIT #################################################

# LoadModule Active Directory

if (!(Get-Module “activedirectory”)) {Import-module activedirectory}

Else {Write-Host “Module Active Directory is al ready loaded”}

# LoadModule VMware PowerCLI

# if (!(Get-Module “VMware.PowerCLI”)) {

#    Find-Module VMware.PowerCLI

#    Install-Module -Name VMware.PowerCLI -Scope CurrentUser

#}

#Else

# {

# Write-Host “Module PowerCLI is al ready loaded”

# }

#Config

$ouservers=”OU=Servers,DC=wardvissers.nl,DC=nl”

$ougroup=”OU=GroepObjecten,DC=wardvissers,DC=nl”

$folder=”Applicatie Servers”

$DestinationVC =”vcenter01.wardvissers.nl

#Username

if (!$username ) { $username = Read-Host “Give vCenter username ‘wardvissers\admin'”}

#Password

if ( -NOT $Password ) {

$PasswordSec = Read-Host “Give vCenter password” -AsSecureString

$Password = [Runtime.InteropServices.Marshal]::PtrToStringAuto([Runtime.InteropServices.Marshal]::SecureStringToBSTR($PasswordSec))

}

#Connect vCenter

$ConnectVC = Connect-VIServer $DestinationVC -Username $Username -Password $Password -AllLinked

$AllVMs = @()

$AllVMs = Import-Csv “D:\TempVMlist.csv”

foreach ($vm in $AllVMs) {

#Haal De Gegevens op

$server=$($vm.server)

$memory=$($vm.memory)

$cpu=$($vm.cpu)

$DestinationCluster=$($vm.DestinationCluster)

$OSSpec=”$($vm.OSCustomizationSpec)”

$VMtemplate=$($vm.VMtemplate)

$group=$($vm.adgroup)

$harddisk1=$($vm.harddisk1)

$harddisk2=$($vm.harddisk2)

Write-Host “$server heeft $memory GB memory en $cpu cpu(‘s)”

if ($server.length -gt 15) {

Write-Output “Hostname cannot contain more than 15 characters.”

$server = Read-Host “Re-enter hostname for host $server”}

Else

{

Write-Host “Server is umc server”

#Maak AD Groep aan en Computer Account

New-ADComputer -Name $server -Path $ouservers -Enabled $true

New-ADGroup -Name “DLG.$server” -SamAccountName “DLG.$server” -GroupCategory Security -GroupScope DomainLocal -DisplayName “DLG.$server” -Path $ougroup

Add-ADGroupMember -Identity “DLG.$server” -Members $group

}

# Rol server uit van Template

# Select the host with the less used memory

$DestinationHost = Get-Cluster –Name $DestinationCluster –Server $DestinationVC | Get-VMhost -State Connected | Sort-Object -Property MemoryUsageGB | Select-Object -First1

# Select DataStore with the most free space and not in maintance

$destinationDatastore = Get-Cluster $DestinationCluster | Get-Datastore | Where {$_.State -ne “Maintenance”} | Sort-Object -Property FreeSpaceGB -Descending | Select-Object -First 1

# Finally, I deploy my VM with the New-VM cmdlet using my template and OS specs. I place the VM on the ESXi host and store the VM on the datastore.

New-VM -Name $server -Template $VMTemplate -OSCustomizationSpec $OSSpec -VMHost $DestinationHOST -Datastore $DestinationDatastore -Location $folder

Get-VM $server | Set-VM -NumCpu $cpu -MemoryGB $memory -Confirm:$false

if ($harddisk1 -gt 60){Get-HardDisk -vm $server | Where {$_.Name -eq “Hard disk 1”} | Set-HardDisk -CapacityGB $harddisk1 -Confirm:$false}

if ($harddisk2 -gt 20) {Get-HardDisk -vm $server | Where {$_.Name -eq “Hard disk 2”} | Set-HardDisk -CapacityGB $harddisk2 -Confirm:$false}

Get-VM $server | Start-VM -Confirm:$false

Get-VM $Server | Get-NetworkAdapter | Set-NetworkAdapter -Connected $true -Confirm:$false

}

Microsoft Exchange Memory Corruption Vulnerability

A remote code execution vulnerability exists in Microsoft Exchange software when the software fails to properly handle objects in memory. An attacker who successfully exploited the vulnerability could run arbitrary code in the context of the System user. An attacker could then install programs; view, change, or delete data; or create new accounts.

Exploitation of the vulnerability requires that a specially crafted email be sent to a vulnerable Exchange server.

The security update addresses the vulnerability by correcting how Microsoft Exchange handles objects in memory.

Download:

Product Link
Microsoft Exchange Server 2010 Service Pack 3 Update Rollup 21

4091243

Microsoft Exchange Server 2013 Cumulative Update 19

4092041

Microsoft Exchange Server 2013 Cumulative Update 20

4092041

Microsoft Exchange Server 2013 Service Pack 1

4092041

Microsoft Exchange Server 2016 Cumulative Update 8

4092041

Microsoft Exchange Server 2016 Cumulative Update 9

4092041

Important information before upgrading to vSphere 6.7 (KB53704)

This article provides important documentation and upgrade information that must be reviewed before upgrading to vSphere 6.7.


Resolution


Compatibility considerations

TLS protocols

These products are not compatible with vSphere 6.7 at this time:

  • VMware NSX
  • VMware Integrated OpenStack (VIO)
  • VMware vSphere Integrated Containers (VIC)
  • VMware Horizon

Environments with these products should not be upgraded to vSphere 6.7 at this time. This article and the VMware Product Interoperability Matrixes will be updated when a compatible release is available.

Upgrade Considerations

Before upgrading your environment to vSphere 6.7, review these critical articles to ensure a successful upgrade
For vSphere

Upgrades to vSphere 6.7 are only possible from vSphere 6.0 or vSphere 6.5. If you are currently running vSphere 5.5, you must first upgrade to either vSphere 6.0 or vSphere 6.5 before upgrading to vSphere 6.7.

For vCenter Server

For Distributed Virtual Switches

Windows Defender Browser Protection for Google Chrome

Safeguarding you from malicious websites

The Windows Defender Browser Protection extension for Google Chrome allows you to add an additional layer of protection when browsing online, powered by the same trusted intelligence found in Microsoft Edge. The extension alerts you about known malicious links, and gives you a clear path back to safety.

https://browserprotection.microsoft.com/learn.html